logoShaping Tomorrow's Built Environment Today

Interpretation For Standard 90.1-2004

Share This

NOTE: All documents linked from this page are in pdf_icon.png PDF-format.

pdf_icon.png Interpretation 90.1-2004-1 - June 25, 2005 (refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 5.2.1 Compliance, relating to gross wall area.)

pdf_icon.png Interpretation 90.1-2004-2 - January 21, 2006 (refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 6.5.3.1 Fan Power Limitation, and Table 6.5.3.1, specifically relating to fan power limitation ratios.)

pdf_icon.png Interpretation 90.1-2004-3 - January 22, 2006 (refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 6.5.6.1 Exhaust Air Energy Recovery, specifically relating to Exception (i) to 6.5.6.1, ventilation air treatment for systems requiring dehumidification.)

pdf_icon.png Interpretation 90.1-2004-4 - January 23, 2006 (refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 11.3.2(d) HVAC Systems, relating to minimum outdoor air ventilation rates to be used for the budget building design and the proposed building.)

pdf_icon.png Interpretation 90.1-2004-5 - January 23, 2005 (refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Table 6.8.1A and Table 6.8.1B requiring a 12.0 SEER and 7.4 HSPF for less than 65,000 Btu/h cooling capacity machines.)

pdf_icon.png Interpretation 90.1-2004-6 - January 28, 2007 (refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Sections 6.2 and 6.4.1.1 and Table 6.8.1C relating to mandatory equipment efficiency requirements for water cooled chillers.)

pdf_icon.png Interpretation 90.1-2004-7 - April 2, 2007 (refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Table 3.1 and Sections 3.2 and 5.4.3.4, regarding vestibules.)

pdf_icon.png Interpretation 90.1-2004-8 - October 12, 2007 (refers to the requirements in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section G2.4 relating to energy rates.)

pdf_icon.png Interpretation 90.1-2004-9 - October 13, 2007 (refers to the requirements in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 11.3.2 and Table 11.3.2A, regarding the Energy Cost Budget Method – Budget Systems Modeling.)

pdf_icon.png Interpretation 90.1-2004-10 - October 12, 2007 (refers to the requirements in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 11, Figure 11.3.2 and Table 11.3.2A, related to the Energy Cost Budget Method and determination of the Budget System Type for geothermal water to water heat pumps.)

pdf_icon.png Interpretation 90.1-2004-11 - October 12, 2007 (refers to the requirements in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 6.5.2.1, regarding the reduction of zone air volume before reheat is allowed.)

pdf_icon.png Interpretation 90.1-2004-12 - October 12, 2007 (refers to the requirements in ANSI/ASHRAE/IESNA Standard 90.1-2004, 6.5.2.1, Exception (b), regarding reheat.)

pdf_icon.png Interpretation 90.1-2004-13 - October 12, 2007 (refers to the requirements in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 6.5.7.2(a), regarding fume hood VAV.)

pdf_icon.png Interpretation 90.1-2004-14 - October 12, 2007 (refers to the requirements in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 6.4.1.2 and Tables 6.8.1C and 6.8.1H through J, regarding centrifugal chiller efficiencies.)

pdf_icon.png Interpretation 90.1-2004-15 - October 12, 2007 (refers to the requirements in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 6.4.1.2 and Tables 6.8.1C and 6.8.1H through J, regarding centrifugal chiller efficiencies.)

pdf_icon.png Interpretation 90.1-2004-16 - March 19, 2008 (refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 5.5.4.2.2, regarding skylights)

pdf_icon.png Interpretation 90.1-2004-17 - April 12, 2008 (refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 2.3(c), regarding the Scope and the applicability of the Standard to Commercial Datacom Facilities.)

pdf_icon.png Interpretation 90.1-2004-18 - June 21, 2008 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section G3.1.2.5, regarding ventilation rate and outdoor air (OA) volume.)

pdf_icon.png Interpretation 90.1-2004-19 - June 21, 2008 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Sections G2.2, G2.5 and G3.1, regarding the application of exceptional calculation methods and nonstandard efficiency measures to model energy for systems utilizing elevated air speed to increase the maximum temperature for acceptable comfort.)

pdf_icon.png Interpretation 90.1-2004-20 - June 22-23, 2008 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 2.3(c), regarding the Scope and the applicability of the Standard to Commercial Datacom Facilities, and interpretation IC 90.1-2004-17.)

pdf_icon.png Interpretation 90.1-2004-21 - June 21, 2008 (Refers refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 9.6.1 and Table 9.6.1, regarding Atrium lighting power density.)

pdf_icon.png Interpretation 90.1-2004-22 – October 3, 2008 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Table 9.6.1, Lighting Power Densities Using the Space-by-Space Method, regarding space types.)

pdf_icon.png Interpretation 90.1-2004-23 – October 3, 2008 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section G3 and Table G3.1, regarding building envelope and the calculation of proposed and baseline building performance.)

pdf_icon.png Interpretation 90.1-2004-24 – October 3, 2008 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 2.3(c), regarding the Scope and the applicability of the Standard to Commercial Datacom Facilities, and Interpretation IC90.1-2004-20 approved June 22 and 23, 2008.)

pdf_icon.png Interpretation 90.1-2004-25 – October 3, 2008 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section G3.1 and Table G3.1, No. 4, regarding schedules for the proposed and baseline buildings.)

pdf_icon.png Interpretation 90.1-2004-26 – October 3, 2008 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Sections 5.8.2, 5.8.2.1 and 5.8.2.2, regarding fenestration rating and labeling.)

pdf_icon.png Interpretation 90.1-2004-27 – January 24, 2009 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section G3.1 and Table G3.1, regarding purchased chilled water.)

pdf_icon.png Interpretation 90.1-2004-28 – January 24, 2009 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 9.1.2, regarding lighting alterations.)

pdf_icon.png Interpretation 90.1-2004-29 – January 24, 2009 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Sections 94.1.1 and 9.4.1.2, regarding interior lighting control.)

pdf_icon.png Interpretation 90.1-2004-30 – January 24, 2009 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section G3.1.3.7, regarding type and number of chillers used in the baseline building.)

pdf_icon.png Interpretation 90.1-2004-31 - April 24, 2009 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 6.4.3, regarding HVAC system control and set point overlap restriction.)

pdf_icon.png Interpretation 90.1-2004-32 - April 7, 2011 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 3.2, regarding the definitions for conditioned and semi-heated spaces as they relate to an existing “big box” shell warehouse.)

pdf_icon.png Interpretation 90.1-2004-33 – October 22, 2011 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section 9.1.1, Exception (c), regarding the exception for health or safety lighting.)

pdf_icon.png Interpretation 90.1-2004-34 – June 27, 2010 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Table G3.1 and Sections G3.1.2.8 and 3.1.2.9, regarding modeling requirements for baseline fan power.)

pdf_icon.png Interpretation 90.1-2004-35 – October 21, 2017 (Refers to the requirements presented in ANSI/ASHRAE/IESNA Standard 90.1-2004, Section G3.1.3.15, regarding VAV Fan Part-Load Performance.)

Close