Putting the "R" in ASHRAE
ASHRAE was formed as the American Society of Heating, Refrigerating and Air-Conditioning Engineers by the 1959 merger of American Society of Heating and Air-Conditioning Engineers (ASHAE) founded in 1894 and the American Society of Refrigerating Engineers (ASRE) founded in 1904. With refrigeration literally in its name, ASHRAE offers a wide selection of information and publications concerning refrigeration and refrigerants - from standards and design guides to ASHRAE courses to a monthly column in the ASHRAE Journal, and more. This page is a repository where you can find all refrigeration-related information from ASHRAE.
Refrigeration Technology Committee for Comfort, Process, and Cold Chain encourages the advancement of refrigeration technology and its application. This committee reports to Technology Council. Through its use in refrigeration and air conditioning systems, the refrigeration process is critical to health, comfort, and welfare of humanity.
More information
Available Refrigeration Resources
Choose any of the links below for more information – purchase is easy using the button associated with each item.
Standards 15 and 34 and other refrigeration materials
ASHRAE Handbook - Refrigeration
ASHRAE Handbook - Fundamentals, Chapter 2
ASHRAE Handbook - Fundamentals, Chapter 29
ASHRAE Handbook - Fundamentals, Chapter 30
ASHRAE Handbook - Fundamentals, Chapter 31
ASHRAE/UNEP Refrigeration Resources

ASHRAE and UNEP have worked together to develop several resources for operating climate-conscious, environmentally responsible, and safe RAC systems.
Included among these tools are:
Visit the ASHRAE/UNEP Portal for additional resources.
ASHRAE Technical Committee, 3.1, Refrigerants and Secondary Coolants
TC 3.1 WEBSITE
TC 3.1 FAQ 24, Where can I find more design information on a new refrigerant?
TC 3.1 FAQ 46, What research is ASHRAE conducting regarding new refrigerants?
TC 3.1 FAQ 84, Where can I find information on new refrigerants?
Available Courses in the Field of Refrigeration
Instructor-Led: Variable Refrigerant Flow System Design & Application
Self-Directed Course: Fundamentals of Refrigeration (I-P)
Practical Guidance for Vaccine Refrigerated Transportation and Storage Abstract (June 28, 2021)
ASHRAE-Endorsed Conferences and Events Covering Refrigeration and Refrigerants
World Refrigeration Day 2025- Cool Skills
June 26, 2025
World Refrigeration Day celebrates the people and technologies responsible for creating and maintaining the world we live in, a world dependent upon temperature-controlled environments. Centred around June 26, the event is supported globally by industry, professional groups, scientific and engineering associations, as well as by governments and individuals.
Free Webinars Hosted By ASHRAE
Futuristic Career in Not-In-Kind Cooling Technologies
Organizers: ASHRAE/IIR
Presented Live: Thursday, June 24, 2021
Speakers: Yunho Hwang, Qian Suxin, Kim Jiyeob, Subramanyaravi Annapragada
View Recording
COVID 19 Vaccine distribution Life-Saving Cold-Chain Careers
Organizers: ASHRAE/CIBSE
Presented Live: Friday, June 25th, 2021
Speakers: Nawaz Kashif, Stefan Elbel, Chris Repice
View Recording
Refrigerant Designations
Ammonia industrial refrigeration system
The tables contained on this page list approved refrigerant numbers from ANSI/ASHRAE 34-2022, Designation and Safety Classification of Refrigerants, the latest edition of Standard 34. Find listings for more than 160 refrigerants and refrigerant blends, including their number, chemical name, and chemical formula.
Complete List
New Definitions
Cooling, refrigeration, chilling, freezing, cold chain: The International Institute of Refrigeration (IIR) and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) have developed common definitions for these five terms.
NEW DEFINITIONS
Press Release Announcing New Refrigeration Definitions
April 11, 2019 | ASHRAE and IIR Establish New Definitions of Five Refrigeration Keywords
ASHRAE Guide for Sustainable Refrigerated Facilities and Refrigeration Systems
Comprehensive Guidance on Sustainable Refrigerated Facilities
ASHRAE Guide for Sustainable Refrigerated Facilities and Refrigerated Systems is an in-depth resource for the sustainable design of refrigerated product facilities, covering the latest in refrigeration technology selection through the commissioning of refrigerated facilities. With guidance on topics such as logistics, product handling, facility layout and location, heat loads, and refrigeration system design, this is the most comprehensive resource on designing these specialized facilities.
Purchase
Refrigeration Commissioning Guide
This Guide was developed through cooperation of ASHRAE and the U.S. Department of Energy, in an effort to promote building energy efficiency. Print copies are available for purchase, but you can download an electronic copy for free.
Learn More
ASHRAE Journal Articles on Refrigeration
Refrigeration Applications Column
ASHRAE Journal publishes a monthly column by Andy Pearson on refrigeration and refrigeration applications. Read April's column, Refrigeration Applications: A Design for Life
After an incident or accident there seems to be no end to the people willing to step up and offer an opinion on just where exactly things went wrong. Engineers have a relentless desire to understand things better and I regularly tell my staff that it is smart to learn from your mistakes, but smarter to learn from someone else’s.
Additional Journal articles of interest:
ASHRAE members can download Journal articles for free by logging in with their member credentials.
Refrigeration-Related Press Releases
Aug 27, 2019 - Engineers Without Borders-USA Announces Chill Challenge: Affordable Off-Grid Refrigeration for Developing Countries
Apr 11, 2019 - ASHRAE and IIR Establish New Definitions of Five Refrigeration Keywords
Refrigeration Timelines
In 2004, a series of timelines was put together in recognition of the 100th anniversary of ASRE (American Society of Refrigerating Engineers) a predecessor society of ASHRAE. Three timelines span the years 1748-1999. A pdf includes all three. Note: timelines are in reverse chronological order.
Timeline, 1748-1904
Timeline, 1906-1939
Timeline, 1939-1999
Timeline, 1748-1999
Refrigeration Awards
George C. Briley ASHRAE Journal Article Award
2014 Winning Article – Alternatives to Vapor-Compression HVAC Technologies by William Goetzler; Robert Zogg; Jim Young; and Caitlin Johnson
Milton W. Garland Commemorative Refrigeration Award for Project Excellence
Comfort Cooling Award for Project Excellence
Donald A. Siller Refrigeration Award
Lower-GWP Refrigeration and Air-Conditioning Innovation Award
Leadership Voices
Interviews with Members in the Field of Refrigeration
|
Carlyle Martin Ashley, President of ASRE in 1956-57
William S. Bodinus, ASHRAE Fellow and Life Member
Cecil Bolling, First President of ASHRAE, 1959
George C. Briley, ASHRAE Fellow and Life Member
Leon Buehler, ASRE President, 1955
Ellsworth F. Cassing
Frank H. Faust, ASHRAE President, 1963-64
John H. Fox, ASHRAE President, 1962-63
|
Milton W. Garland
M. T. Gossett
William Holladay, ASHRAE President, 1968-69
Tom Kroeschell
Bernard Nagengast
Alwin B. Newton
Edward Simons
Wilbert F. Stoecker
|
Complete List of Leadership Voices Interviews
VIEW COMPLETE LIST
Refrigeration Pages of Historical Interest
DOMELRE circa 1915 first electric refrigerator
ASRE Indexes to ASRE Transactions, ASRE Journal, and Refrigerating Engineering
Air-Conditioning and Refrigeration Patents
Special Series Commemorating the First Century of Air Conditioning
A Look Back at HVAC&R
Articles about refrigeration of historical interest
Air conditioning still cool after 100 years
The ASHRAE Centennial: 100 Years of Progress (PDF - 13.5 MB)
Report on Domestic Refrigerating Machines, 1923 - 1925
By Alexander Stevenson Jr. (1892-1946).
Documentation of 1920's Carbon Dioxide Air Conditioning System -- Orpheum Theater, Minneapolis, MN
Documented by Bernard Nagengast et al.
History in the Air Conditioning and Refrigeration Industry: Breakthrough of Large Positive Displacement Rotary Compressors in the Second Half of the 20th Century
By Henri Soumerai.